CDQYV - EC-119 EPOXY CURING SOLUTION

Product Identification

Product ID:EC-119 EPOXY CURING SOLUTION
MSDS Date:11/18/1996
FSC:8010
NIIN:00F053047
Kit Part:Y
MSDS Number: CDQYV

Responsible Party
DEXTER CORP PACKAGING PRODUCTS DIV
1 EAST WATER ST
WAUKEGAN, IL 60085-5614
US

Emergency Phone: 847-623-4200

Info Phone: 847-623-4200

Cage: 91342

Contractor
DEXTER CORP THE PACKAGING PRODUCTS DIV
WAUKEGAN, IL 60085-5614 US

Telephone: 847-623-4200

Cage: 91342

Ingredients

ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 10-20%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM


BENZENE (SUSPECTED HUMAN CARC BY ACGIH, IARC, ANIMAL

CAS: 71-43-2

RTECS: CY1400000

ACGIH TLV: 0.3 MG/CUM (A2) IC

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


DIMETHYL AMINMETHYLPHENOL MIXTURE

Fraction By Weight: <10%


BUTANOL, N-BUTYL ALCOHOL, PROPYL CARBINOL, BUTYL ALCOHOL

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: <10%

OSHA PEL 100 PPM

ACGIH TLV: C 152 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL BENZENE *96-4*

CAS: 100-41-4

RTECS: DA0700000

Fraction By Weight: <10%

OSHA PEL 435 MG/CUM

ACGIH TLV: 434 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (IARC CARC- GROUP 3) *96-4*

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 10-20%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


XYLENE, DIMETHYLBENZENE, XYLOL (IARC - GROUP 3) *96-4*

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 40-50%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM, SKIN

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION: IRRITATION TO RESPIRATORY
TRACT. SKIN: IRRITATION, SENSITIZATION. EYES: IRRITATION. CHRONIC
EFFECTS TO THE RESPIRATORY TRACT, CNS, ALLERGIC RESPIRATORY/SKIN
REACTIONS, CORNEAL INJURY, KIDN EYS, LIVER, BLOOD-REPRODUCTIVE
SYSTEM, CARDIAC SENSITIZATION.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:IRRITATION, HEADACHE, DIZZINESS, DROWSINESS.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. EYES: FLUSH W/WATER. SKIN:
WASH W/SOAP & WATER. INGESTION: DRINK WATER. OBTAIN MEDICAL
ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:SCC
Flash Point:44F
Lower Limits:1
Extinguishing Media:WATER FOG, FOAM, DRY CHEMICAL/CO2.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. AVOID BREATHING
VAPORS, VENTILATED AREAS. REMOVE W/INERT ABSORBANT & NON-SPARKING
TOOLS.

Handling

Handling and Storage Precautions:DON'T TAKE INTERNALLY. CONTAINERS
SHOULD BE GROUNDED WHEN POURING. AVOID FREE FALL OF LIQUID IN
EXCESS OF A FEW INCHES.
Other Precautions:MAKE SURE THE DRUM IS COMPLETELY EMPTY BEFORE
ATTEMPTING TO WELD/BRAZE. THE DRUM SHOULD BE INDUSTRIALLY CLEANED
PRIOR TO REUSE. DON'T FLAME CUT, BRAZE/WELD W/O NIOSH APPROVED
RESPIRATOR/APPROPRIATE VE NTILATION. DON'T BREATHE VAPORS/MIST.

Exposure Controls

Respiratory Protection:WHERE GENERAL DILUTION/LOCAL EXHAUST FAILS, WEAR
AN APPROPRIATE, PROPERLY FITTED RESPIRATOR APPROVED BY NIOSH/MSHA
WHEN EXPOSED. AN AIR LINE RESPIRATOR IS RECOMMENDED.
Ventilation:GENERAL DILUTION/LOCAL EXHAUST VENTILATION.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SAFETY GLASSES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:180-300F
Vapor Density:>1
VOC Grams/Liter:6.5

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:WELDING: CO & OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS. UN1263.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their